C. Venting Components
CAUTION! Risk of Cuts/Abrasions/Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
The vertical vent termination system installed on this model
includes:
• One length of 3-inch flexible vent pipe for exhaust air
(included with vent kit).
• One length of 3-inch flexible vent pipe for combustion
air (included with vent kit).
• One vertical termination cap (included with vent kit).
Masonry
LINK-DV30B
LINKSQ-DV30
Installation*
TERMINATION
EXHAUST
AIR
VENT PIPE
INLET AIR
VENT PIPE
*LINK-DV30B/LINKSQ-DV30: This installation may perform better and allow less cold air infiltration in
negative pressure settings.
**LINK-DV430B/LINKSQ-DV4-30:
• This installation may be more susceptible to cold air infiltration and the effects of negative pressure
on the appliance's performance.
• Depending on the chimney cleanliness, consider using the full length intake so as to lessen
the possibility of sense rod contamination and flame rectification issues.
Figure 5.4
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Installation Manual • 2538-980 Rev. E • 5/19
22
LINK-DV4-30B
LINKSQ-DV4-30
Installation**
CAP
EXHAUST
AIR
VENT PIPE
OR
Note: Untwist the
pipe while extend-
ing it, to achieve
full 30' length.
To prevent odors and cold air drafts, it may be necessary to
place non-combustible insulation or field fabricated metal
plates around the vent pipe flues as they go through the
damper.
Note: The LINK-DV4-30B and LINKSQ-DV4-30 systems
REQUIRE this insulation.
Factory Built
Wood Burning
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WOODBURNING PIPE
Remove 18 inch x 18 inch
flashing on cap by removing
3 screws. Connect both the
LINK-ZC-ADPB to Class A
Pipe and the termination cap
to the LINK-ZC-ADPB with
self tapping screws.
Note: Untwist the
pipe while extend-
ing it, to achieve
WARNING:
full 30' length.
DO NOT BLOCK
THIS PIPE END!
INLET AIR
OPTIONAL LINK-ZC-ADPB
VENT PIPE
FOR USE WITH CLASS A
WOODBURNING PIPE
LINK-DV30B
LINKSQ-DV30
Installation*
OR
LINK-DV4-30B
LINKSQ-DV4-30
Installation**