Removing RTX Support

© National Instruments Corporation
The NI 783xR now supports RTX. When you launch LabVIEW, the
NI 783xR appears in the LabVIEW Execution Target menu as FPGA
Device [device name] visa://localhost::RTRTX::0/RIO0::INSTR.
Complete the following steps to remove RTX support from the NI 7831R.
1.
Close all NI software.
2.
Select Start»Program Files»Ardence RTX»RTX»RTX Properties.
3.
On the Plug and Play tab, right-click the name of your device and
select Remove RTX INF Support.
4.
Click Apply. RTX Properties returns a Warning dialog box. Click OK.
5.
In the RTX Properties window, click OK.
6.
Right-click My Computer and select Properties.
7.
Select the Hardware tab and click Device Manager.
8.
For Windows XP, expand RTX Drivers, right-click [device name]
RTX Supported and select Update Driver.
You have removed RTX support for the NI 783xR.