Commissioning the CP 440
3.1

Sequence of Steps to Be Taken

Before starting up the CP 440 you will need to perform the following steps in the
specified sequence.
1. Install the CP 440
2. Configure the CP 440
3. Parameterize the CP 440
4. Save the parameterization data
5. Create a user program for the CP 440
Installing the CP 440
Installing the CP 440 involves inserting it into the mounting rack of your
programmable controller.
For a detailed description, see Chapter 4.
Connecting the CP 440 to the Communication Partner
The connection to your communication partner is made using the connecting cable
described in Appendix B. You can find additional information on setting up the
physical interface in Section 3.2.
Configuring the CP 440
Configuring the CP 440 involves entering it in the configuration table. The CP 440
is configured using the STEP 7 software.
For a detailed description, see Section 5.1.
Parameterizing the CP 440
Parameterizing the CP 440 involves creating the specific parameters of the
protocols. You parameterize the CP 440 with the CP 440: Point-to-Point
Communication, Parameter Assignment parameterization interface.
For a detailed description, see Section 5.2.
Saving the Parameterization Data
Saving the parameterization data of the CP 440 involves saving the parameters,
downloading them to the CPU and transferring them to the CP 440. You use the
STEP 7 software to store the parameterization data.
For a detailed description, see Section 5.4.
3-2
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02