Transmission Times; A.2 Transmission Times - Siemens SIMATIC CP 440 Manual

Installation and parameter assignment
Table of Contents

Advertisement

A.2

Transmission Times

Transmission Times
The tables below indicate the transmission times required depending on the
transmission protocol selected.
Two S7-400s each with a CPU 416 (6ES7 416-2XK02-0AB0) and a CP 440 were
used to measure the times. A SEND_440 FB was programmed in the user
program of the active CPU, and a RECV_440 FB was programmed in the user
program of the passive CPU. The time that elapsed between the initiation and
completion of the job was measured.
ASCII Driver
Transmission times with the ASCII driver:
Table A-3
Transmission Times with the ASCII Driver in ms
115200
Baud rate
(bps)
User data
1 byte
1.5
10 bytes
2
20 bytes
4
50 bytes
6
100 bytes
12
200 bytes
22
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
76800
57600
38400
19200
2
2
2
3
2
3
5
8
5
6
8
14
9
12
17
32
17
22
32
61
32
41
59
117
Technical Specifications
9600
4800
2400
1200
4
8
15
29
14
28
56
111
26
52
102
202
60
120
240
478
118
236
470
936
230
460
920
1835
600
300
55
110
220
440
404
807
952
1906
1872
3740
3668
7330
A-5