Table 8-2
Event Classes and Event Numbers, continued
Event No.
(08)11H
Character frame error
(08)12H
With ASCII driver only:
More characters were received after the
CP had sent XOFF or set CTS to OFF
(08)14H
With ASCII driver only:
A message frame or several message
frames have got lost, because you have
been working without flow control.
(08)16H
The length of a received message frame
was longer than the maximum specified
length.
Event No.
(0B)01H
Receive buffer more than 2/3 full
Event No.
(80)00H
Module firmware does not exist
Point-to-point connection CP 440 Installation and Parameter Assignment
A5E00057742-02
Event
Event class 11 (0B8H):
"Warnings"
Event
Event class 128 (80H):
"Module error"
Event
Diagnostics with the CP 440
Remedy
Check the connecting cable of the
communication partner, or check whether
both devices have same setting for the
transmission rate, parity and number of stop
bits.
Correct fault by changing system setup or
line installation.
Reparameterize the communication partner,
or deal with the data in the CP more quickly.
Work with flow control as much as you can.
Use the entire receive buffer. Set the
"Reaction to CPU Stop" parameter in the
basic parameters to "Continue".
Correction required at the partner
Remedy
Call the receive block more often to avoid
the receive buffer overflowing.
Remedy
Carry out a firmware update.