Installing VIP X1600 modules

Installing the different VIP X1600 modules in the VIP X1600 base is described
in the relevant Quick Installation Guide. Please also take note of the following
basic notes when installing a unit.
Caution
Do not install a VIP X1600 module in a different housing and do not operate
the unit outside of the VIP X1600 base. The ambient temperature during in-
stallation must be between 0 and +50 °C (+32 und +122 °F), and the relative
humidity must not exceed 80% (non-precipitating).
Installation sequence and capacity of the VIP X1600 base
You can install up to four VIP X1600 modules in a VIP X1600 base.
Slot 1 must always be the first slot that is populated. The remaining slots can be
populated in any order desired. It is possible to mount and remove modules in
slots 2 to 4 during operation without interrupting the power supply.
Caution
Disconnect the VIP X1600 base from the power supply before installing a
module in Slot 1.
Ensure that Slot 1 is populated by a module, even when modifying the installa-
tion.
Cooling
The installed VIP X1600 modules generate a high volume of heat during opera-
tion. As a result, it is essential that a functional heat dissipation system is in place
for problem-free operation of a VIP X1600.
Caution
Whenever the installation is modified, or modules are exchanged or sup-
plemented, it is essential that all unpopulated slots are properly covered
on the rear side of the VIP X1600 base.
Installation
Installation and Operating Manual | VIP X1600
Bosch Security Systems | 2006-03 | V2.0