Installing in a switch cabinet

The VIP X1600 is set up for installing in a 19-inch rack. The necessary installa-
tion equipment is contained in the components supplied.
Caution
When installing in a switch cabinet, ensure that there is sufficient ventila-
tion for the unit. There must be at least 5 cm (1.97 in.) of free space to the
left and right of the unit and at least 10 cm (3.94 in.) at the rear.
The VIP X1600 generates heat during operation. During installation,
please note the maximum heat value of 205 BTU/h.
When mounting additional units, direct contact with the VIP X1600 is per-
mitted provided that the surface temperature of the adjacent units does not
exceed +50 °C (+122 °F).
When installing in a switch cabinet, ensure that the screw joints are free of ten-
sion and subject to as little mechanical stress as possible. Ensure that the unit
and the power supply units have sufficient grounding.
Installing and connecting the VIP X1600
Caution
Only use power supply units approved by Bosch Security Systems to sup-
ply power.
– Prepare the switch cabinet in such a manner that you are easily able to insert
the VIP X1600 directly at the installation point.
– Place the cage nuts in the corresponding bores or spaces in the switch cab-
inet frame.
– Lift the VIP X1600 into the switch cabinet frame and insert the fastening
screws together with the washers.
– Tighten the screws one after the other and then check once more that all the
screws are tight.
– Connect one or two power supply units to the sockets on the rear of the hous-
ing. Hand tighten the coupling nuts for the plug.
Installation
Installation and Operating Manual | VIP X1600
Bosch Security Systems | 2006-03 | V2.0