Example
The following example would be used to specify the complex qualifier shown
in figure 6-2.
OUTPUT XXX;":MACHINE1:STRIGGER:BRANCH1 '((A OR B) AND (F OR
G))', 2"
Terms A through E, RANGE 1, and TIMER 1 must be grouped together
and terms F through J, RANGE 2, and TIMER 2 must be grouped together.
In the first level, terms from one group may not be mixed with terms from the
other. For example, the expression
not allowed because the term C cannot be specified in the F, G, and I group.
In the first level, the operators you can use are
XOR, NXOR
groups together. It is acceptable for a group to consist of a single term.
Thus, an expression like
simple terms from separate groups.

CLEar

Command
:MACHine{1|2}:STRigger:CLEar
{All|SEQuence|RESource}
The CLEar command allows you to clear all settings in the State Trigger
menu, clear only the Sequence levels, or clear only the resource term
patterns. Cleared settings are replaced with the defaults.
Example
OUTPUT XXX;":MACHINE1:STRIGGER:CLEAR RESOURCE"
((A OR IN_RANGE2) AND (C OR G))
. Either
or
may be used at the second level to join the two
AND
OR
(B AND G)
STRigger (STRace) Subsystem
AND, NAND, OR, NOR,
is legal, since the two operands are both
CLEar