Threshold - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

SFORmat Subsystem

THReshold

THReshold
Command
:MACHine{1|2}:SFORmat:THReshold<N>
{TTL|ECL|<voltage>}
The THReshold command allows you to set the voltage threshold for a given
pod to ECL, TTL, or a specific voltage from −6.00 V to +6.00 V in 0.05 volt
increments.
an integer from 1 to 12 indicating pod number
<N>
real number between −6.00 to +6.00
<voltage>
default value of +1.6 V
TTL
default value of −1.3 V
ECL
Example
OUTPUT XXX;":MACHINE1:SFORMAT:THRESHOLD1 4.0"
Query
:MACHine{1|2}:SFORmat:THReshold<N>?
The THReshold query returns the current threshold for a given pod.
Returned Format
[:MACHine{1|2}:SFORmat:THReshold<N>] <value><NL>
Example
OUTPUT XXX;":MACHINE1:SFORMAT:THRESHOLD4?"
5–18