Accumulate; Acquisition - HP 16554A Programmer's Manual

State/timing logic analyzers
Table of Contents

Advertisement

ACCumulate

Command
:MACHine{1|2}:SWAVeform:ACCumulate
{{ON|1}|{OFF|0}}
The ACCumulate command allows you to control whether the waveform
display gets erased between individual runs or whether subsequent
waveforms are allowed to be displayed over the previous waveforms.
Example
OUTPUT XXX;":MACHINE1:SWAVEFORM:ACCUMULATE ON"
Query
MACHine{1|2}:SWAVeform:ACCumulate?
The ACCumulate query returns the current setting. The query always shows
the setting as the characters, "0" (off) or "1" (on).
Returned Format
[MACHine{1|2}:SWAVeform:ACCumulate] {0|1}<NL>
Example
OUTPUT XXX;":MACHINE1:SWAVEFORM:ACCUMULATE?"

ACQuisition

Command
:MACHine{1|2}:SWAVeform:ACQuisition {AUTOmatic|MANual}
The ACQuisition command allows you to specify the acquisition mode for the
state analyzer. The acquisition modes are automatic and manual.
Example
OUTPUT XXX;":MACHINE2:SWAVEFORM:ACQUISITION AUTOMATIC"
SWAVeform Subsystem
ACCumulate
8–5

Advertisement

Table of Contents
loading

This manual is also suitable for:

16555d16555a

Table of Contents