Panel Connectors and Wiring
Any USB peripherals (mouse, keyboard, etc.) may be connected to one of the two
USB ports on the rear of the device (FIG. 2). Updates to the device's firmware are also
made via the USB ports
.
Entry for RJ45/
USB Ports
FIG. 2
Connectors on the rear of the MXT-700

Power via Power Over Ethernet

Power for the MXT-700 is supplied via Power Over Ethernet (PoE), utilizing an AMX-
certified, capacitive touch-compliant PoE injector such as the PS-POE-AT High Power
PoE Injector (FG423-81) or equivalent PoE device. If using a PoE injector, the PoE
injector should be installed between the MXT-700 and the incoming Ethernet cable,
and connected to the RJ45 port on the cable attached to the device (FIG. 3)
RJ45 Port
FIG. 3
Back of the MXT-700, showing RJ45 port and cable for PoE

Ethernet Cable Installation and Modification

In installations where you wish to conceal the Ethernet cable, a hole at least 1.00"
(2.54 cm) in diameter is required in the surface to allow passage of the female RJ45
connector (FIG. 3). If using a smaller hole is unavoidable, you will need to disconnect
the Ethernet cable (ECA5968-05) from the device.
NOTE: The minimum diameter hole through which the Ethernet cable may pass is
0.50" (1.27 cm).
MXT-700
FIG. 4
Bottom of the MXT-700
To disconnect and reconnect the MXT-700's Ethernet cable to allow use of a hole
smaller than 1.00" in diameter:
1.
On a soft surface, turn the MXT-700 face-down to access the bottom of the
device.
2.
Remove the clamp holding the Ethernet cable (FIG. 4) until the Ethernet cable
moves freely.
3.
Remove the Ethernet cable connector and pull the cable out of the clamp.
4.
Pass the Ethernet cable (ECA5968-05) through the hole, with the RJ45
connector on the other side of the installation surface from the device.
5.
Press the Ethernet cable back into the clamp. Do NOT tighten the clamp at this
time.
6.
Using a nonconductive item such as a wooden stick, reinsert the Ethernet cable
connector into the device. Use the stick to ensure that the connector is properly
seated.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
Speaker
PoE Cable
Cable length
edited for clarity
Ethernet Cable
Clamp
Connector
7/12
AMX reserves the right to alter specifications without notice at any time.
7.
Tighten the clamp to secure the Ethernet cable. Make sure the clamp is around
the bundled black cable, not the individual wires.
8.
Connect the RJ45 connector to its incoming Ethernet cable and apply power.
Configuring the MXT-700
The MXT-700 is equipped with Settings Pages that allow you to set and configure
various features on the panel. For more information on connecting and configuring the
MXT-700 to a network, please refer to the Modero X Series Programming Guide,
available at www.amx.com.
Accessing the Settings Pages
To access the Settings Pages on the MXT-700, press and hold the Sleep Button
(FIG. 1) on the top of the panel for 3 seconds. The user will be prompted to release the
button to enter the Settings page.
Accessing the Configuration Page
1.
From the Settings Page, select Configuration. If the Configuration page is
password protected, this opens a password keypad.
2.
Enter the panel password into the keypad (the default is 1988) and select OK to
access the page.
Setting the Panel's Device Number and Device Name
In the Configuration page:
1.
Press Panel to open the Panel Configuration page.
2.
Ensure that the Synchronize Device Names button is not selected, and click it to
deselect it if it is.
.
3.
Press Device Number to open the Device Number keypad.
4.
Enter a unique Device Number assignment for the panel and press OK.
5.
Press the Device Name field to open the Device Name keypad.
6.
Enter a unique Device Name assignment for the panel and press OK.
7.
Click the arrow on the top left of the page once to return to the Configuration
page and twice to return to the Settings page.
Accessing the Connection & Networks Page
1.
From the Settings Page, select Connection & Networks. If the page is password
protected, this opens a password keypad.
2.
Enter the panel password into the keypad (the default is 1988) and select OK to
access the page.
Connecting to a Master
The panel requires that you establish the type of connection you want to make
between it and your Master.
In the Connection & Networks page:
1.
Select Master Connection to open the Master Connection page
2.
Press Mode to toggle through the available connection modes:
Connection Modes
Mode Description
Auto
The device connects to the first
master that responds.
This setting requires that you set
the System Number.
URL
The device connects to the
specific IP of a master via a TCP
connection.
This setting requires that you set
the Master's IP.
Listen
The device "listens" for the
Master to initiate contact.
This setting requires you provide
the master with the device's IP.
3.
If you have enabled password security on your Master, you need to set the user-
name and password within the device.
a. Select Username to open the Master User keyboard.
b. Set your Username and select OK.
c. Select the Password to open the Master Password keyboard.
d. Set your Master Password and select OK.
e. Press the Back button twice to return to the Settings page.
Configuring the Panel to a Network
The first step is to configure the panel's communication parameters. This only
configures the panel to communicate with a network, and it is still necessary to tell the
panel with which Master it should be communicating.
Network Communication With a DHCP Address
In the Connection & Networks page:
1.
Select Network Connection to open the Network Connection page.
2.
Toggle the DHCP/Static field until the choice cycles to DHCP. This action causes
all fields on the page (other than Host Name) to be greyed-out.
3.
Select Host Name to open the Host Name keyboard. Enter the new host name
and click OK.
Procedures
Setting the System Number:
1. Select Master System Number to open
the keypad.
2. Set your Master System Number and
select OK.
Setting the Master IP:
1. Select the Master IP number to the
keyboard.
2. Set your Master IP and select OK.
Confirm device IP is on the Master URL list.
You can set the Host Name on the device
and use it to locate the device on the master.
Host Name is particularly useful in the DHCP
scenario where the IP address can change.
93-5968-04