Marco DUSTMASTER Operator's Manual page 32

28,000 cfm tier 4 diesel dust collectors
Table of Contents

Advertisement

W-562
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
W-586
Moving parts can
present an area where
crushing, pinching,
entanglement or
amputation may occur.
Do not place body parts
or foreign objects in any
area where there are
moving parts. Failure to
comply with the above
warning could result in
death or serious injury.
31
Dustmaster
28,000 CFM Tier 4 Diesel Dust Collectors
®
TROUBLESHOOTING
SYMPTOM (Cause)
Discharge Augers do not turn
(Object in auger, hydraulic fluid levels,
hydraulic pressure relief valve, hydraulic
pump, hydraulic motor, stripped gear,
broken chain)
Magnehelic Gauge reading
greater than normal operating
range
(Dust Collector Filter Cartridges)
ACTION
Run Discharge Auger in reverse to dislodge
item. Dismantle Discharge Auger if object
still lodged.
Fill hydraulic system with hydraulic fluid.
Check line pressure at by-pass gauge, reset
or replace hydraulic valve.
Test hydraulic pump pressure. Replace
hydraulic pump.
Bench test hydraulic motor. Repair or
replace hydraulic motor.
A reading greater than 10" (w.c) on
Magnehelic Gauge indicates clogged filters.
Decrease engine RPM to idle speed and
disengage clutch while allowing engine to
run. Pulsers will clean down the filters. Once
gauge reads back into the normal operation
range of 3" – 10" (w.c), re-engage clutch and
increase RPM to operating speed.
If Magnehelic Gauge is reading above 10"
(w.c.), perform After Use procedure. Inspect
Pulser System and Filters. Replace filter
cartridges, if needed.
If Magnehelic Gauge is reading above 15"
(w.c.), shut down unit immediately. Replace
filter cartridges.