Remove & Install Dust Collector Filter Cartridges - Marco DUSTMASTER Operator's Manual

28,000 cfm tier 4 diesel dust collectors
Table of Contents

Advertisement

W-562
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
W-501
Breathing dust
containing silica could
cause silicosis, a fatal
lung disease. Breathing
dust during abrasive
blasting operations,
post-blast cleaning
operations, and/or
servicing equipment
within the abrasive
blasting area may
expose an individual to
conditions that could
cause asbestosis,
lead poisoning and/or
other serious or fatal
diseases. Harmful
dust containing toxic
material from abrasives
or surfaces being
abrasive blasted can
remain suspended in
the air for long periods
of time after abrasive
blasting has ceased. A
NIOSH-approved, well-
maintained, respirator
designed for the
specific operation being
performed must be used
by anyone abrasive
blasting, handling or
using the abrasive, and
anyone in the area of the
dust. Failure to comply
with the above warning
could result in death or
serious injury.
27
Dustmaster
28,000 CFM Tier 4 Diesel Dust Collectors
®
MAINTENANCE
Remove & Install Dust Collector Filter Cartridges
1) Remove Compression Coupling (2) from
Pulser System Blowpipe (1).
2) Remove Pulser System Blowpipe (1).
3) Remove four Washers and Nuts (3) and
remove Filter Retainer (4). Repeat for
remaining Filter Retainers.
4) Remove Filter Cartridge (5). Repeat for
remaining Filter Cartridges.
5) Install parts in reverse order.
2
1
4
3
5

Advertisement