Maintenance; Remove & Install Fan Drive Belt - Marco DUSTMASTER Operator's Manual

28,000 cfm tier 4 diesel dust collectors
Table of Contents

Advertisement

W-562
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
W-586
Moving parts can
present an area where
crushing, pinching,
entanglement or
amputation may occur.
Do not place body parts
or foreign objects in any
area where there are
moving parts. Failure to
comply with the above
warning could result in
death or serious injury.
W-590
When performing
service or maintenance
on systems or devices
requiring access from
an elevated position,
you must comply
with all OSHA, local,
City, State, Province,
Country and jurisdiction
regulations, ordinances
and standards, as
related to working in
elevated work areas.
Failure to comply with
the above warning
could result in death or
serious injury.
21
Dustmaster
28,000 CFM Tier 4 Diesel Dust Collectors
®

MAINTENANCE

Remove & Install Fan Drive Belt
1) Disconnect battery cables from battery.
2) Remove six Bolts and Washers (2).
3) Remove Front Belt Cover (1).
4) Loosen four Bolts (4).
5) Rotate two Bolts (5) counter-clockwise until
Belt (3) is loose and can be removed.
6) Remove Belt (3) and replace.
7) Adjust fan drive belt tension. (See Adjust
Tension of Fan Drive Belt.)
8) Install parts in reverse order.
3