Connect Duct Hose - Marco DUSTMASTER Operator's Manual

28,000 cfm tier 4 diesel dust collectors
Table of Contents

Advertisement

W-562
Always depressurize
the entire system,
disconnect all power
sources and lockout/
tagout all components
before any maintenance
or troubleshooting is
attempted. Failure to
comply with the above
warning could cause
electrical shock and
inadvertent activation of
equipment resulting in
death or serious injury.
N-536
When a dust collector
is used to service a
storage tank, ensure
there is adequate
ventilation to prevent
tank collapse due to
pressure imbalance
between external and
internal tank surfaces.
Failure to properly
ventilate storage tank
may result in damage
to property. If proper
ventilation is in
question, consult with
tank manufacturer or
engineer.
OPERATING INSTRUCTIONS

Connect Duct Hose

1) Secure a Duct Hose (not shown) to Dust Collection Inlet (A,B,C, or D). See
Configuration Chart, below.
Note: Using only one Duct Hose will result in diminished performance.
2) Use Support rail in place above Dust Collection Inlets to assist in securing Duct Hose.
3) Connect opposite end of Duct Hose (not shown) to Containment Area. Containment
Area should have sufficiently sized air inlet openings on opposite side for air exchange
and cross-flow ventilation.
B
A
Duct Hose Configurations:
A + D
A + C
B + D
B + C
Dustmaster
28,000 CFM Tier 4 Diesel Dust Collectors
®
C
D
12

Advertisement

Table of Contents
loading

Table of Contents