OPERATING INSTRUCTIONS

Reading Magnehelic Gauge

Reading Magnehelic Gauge (Dust Collector Differential Pressure) Instructions:
The Magnehelic Gauge provides a means to tell how clean the dust collector filter
cartridges are. It measures the static pressure and the resistance of air flow across the
filters.
• New Filters will register approximately 1" water column (w.c.) on the gauge. Normal
operating range for conditioned filters will show 3" – 14" (w.c) on gauge.
• If Magnehelic Gauge is reading above the normal operating range, see Troubleshooting
Section.
• If reading above 14" (w.c.), stop operating the unit, perform shut-down procedure, and
check pulser system and filter cartridges.
• If reading above 16" (w.c.), stop operating the unit, perform shut-down procedure, check
pulser system, and if static pressure will not drop below 16", replace filter cartridges.