Assignment, Terminal Boxes And Max. Cross-Sections - Siemens SINAMICS S 1PH7 Configuration Manual

Induction motors for machine tools
Table of Contents

Advertisement

Assignment, terminal boxes and max. cross-sections

Table 6- 1
Assignment, terminal boxes and max. cross-sections
Shaft
Motor type
height
100
1PH710☐-☐☐☐
132
1PH713☐-☐☐☐
160
1PH716☐-☐☐☐
180
1PH7184-☐☐☐
1PH7186-☐☐D
1PH7186-☐☐E
1PH7186-☐☐F
1PH7186-☐☐L
1PH7186-☐☐T
225
1PH7224-☐☐C
1PH7224-☐☐D
1PH7224-☐☐F
1PH7224-☐☐L
1PH7226-☐☐D
1PH7226-☐☐F
1PH7226-☐☐L
1PH7228-☐☐D
1PH7228-☐☐F
1PH7228-☐☐L
Current load capability based on IEC 60204-1, routing type C, Table 5.
1)
Depending on design of the metric cable gland
2)
1PH7 induction motors (Machine tools)
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
Terminal
Cable
Max.
box type
entry
possible
outer
cable
diameter
Valid for the 8th
position of the Order
No. "2", "4", "6"
integrated
PG 29
integrated
PG 36
integrated
PG 40
1XB7322
2 x PG 42
1XB7322
2 x PG 42
1XB7322
2 x PG 42
1XB7422
2 x M 72 x 2
1XB7422
2 x M 72 x 2
1XB7322
2 x PG 42
1XB7322
2 x PG 42
1XB7322
2 x PG 42
1XB7322
2 x PG 42
1XB7700
3 x M 72 x 2
1XB7422
2 x M 72 x 2
1XB7700
3 x M 72 x 2
1XB7700
3 x M 72 x 2
1XB7700
3 x M 72 x 2
1XB7700
3 x M 72 x 2
1XB7700
3 x M 72 x 2
Cable entry Max.
possible
outer
cable
diam-
2)
eter
Valid for the 8th
position of the Order
No. "7", "8"
28
M 32 x 1.5
34
M 40 x 1.5
40
M 50 x 1.5
40
2 x M 50 x 1.5
40
2 x M 50 x 1.5
40
2 x M 50 x 1.5
56
2 x M 63 x 1.5
56
2 x M 63 x 1.5
40
2 x M 50 x 1.5
40
2 x M 50 x 1.5
40
2 x M 50 x 1.5
40
2 x M 50 x 1.5
56
3 x M 75 x 1.5
56
2 x M 63 x 1.5
56
3 x M 75 x 1.5
56
3 x M 75 x 1.5
56
3 x M 75 x 1.5
56
3 x M 75 x 1.5
56
3 x M 75 x 1.5
Connection system
6.2 Power connection
Number of
Max.
main
connect
terminals
able
cross-
section
per
2)
terminal
[mm
21
6 x M 5
25
28
6 x M 6
35
38
6 x M 6
50
38
3 x M 12
2 x 50
38
3 x M 12
2 x 50
38
3 x M 12
2 x 50
53
3 x M 12
2 x 70
53
3 x M 12
2 x 70
38
3 x M 12
2 x 50
38
3 x M 12
2 x 50
38
3 x M 12
2 x 50
38
3 x M 12
2 x 50
68
3 x 2 x M 12
3 x 150
53
3 x M 12
2 x 70
68
3 x 2 x M 12
3 x 150
68
3 x 2 x M 12
3 x 150
68
3 x 2 x M 12
3 x 150
68
3 x 2 x M 12
3 x 150
68
3 x 2 x M 12
3 x 150
Max.
pos-
sible
current
for
each
ter-
]
minal
2
1)
[A]
84
104
123
191
191
191
242
242
191
191
191
191
583
242
583
583
583
583
583
213