Cables On Motors With Drive-Cliq; Encoder Connection For Motors Without Drive-Cliq - Siemens SINAMICS S 1PH7 Configuration Manual

Induction motors for machine tools
Table of Contents

Advertisement

Connection system
6.6 Signal connection

Cables on motors with DRIVE-CLiQ

With DRIVE-CLiQ, the same cable is used for all encoder types. Only pre-assembled cables
from Siemens (MOTION-CONNECT) may be used.
Table 6- 6
6FX ☐ 002
For other technical data and length code, refer to Catalog, Chapter "MOTION-CONNECT
connection system"

Encoder connection for motors without DRIVE-CLiQ

Motors that are not equipped with DRIVE-CLiQ require a Cabinet-Mounted Sensor Module
when operated with SINAMICS S120. The Sensor Modules evaluate the signals from the
connected motor encoders or external encoders and convert them to DRIVE-CLiQ. In
conjunction with motor encoders, the motor temperature can also be evaluated using Sensor
Modules. For additional information, refer to the SINAMICS Manual.
Figure 6-7
220
Pre-assembled cable
- ☐DC☐☐
- ☐☐☐
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
Encoder connection for motors without DRIVE-CLiQ
0
↓↓↓
Length
max. cable length 100 m
max. cable length 50 m
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
1PH7 induction motors (Machine tools)