Adaptation To Different Types Of Gas - Smeg WIL61BVM Instruction Manual

Smeg gas oven instruction manual
Table of Contents

Advertisement

Instruction for the installer

3 ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.
The cooker hob is set for LPG G30/G31 (3+) at a pressure of 28/37 mbar. In the case of functioning
with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the
gas taps. To change the nozzles, proceed as described below.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in paragraph "3.2 /
3.3 Burner and nozzle characteristics table".
4. Replace the burners in the correct position.
8

Advertisement

Table of Contents
loading

Table of Contents