Tracvision 4 Field Replaceable Units - KVH Industries TracVision 4 Technical Manual

Hide thumbs Also See for TracVision 4:
Table of Contents

Advertisement

TracVision 4 Installation and Technical Manual
TracVision 4 components receive
power from multiple sources. Do
not open any electrical assemblies
or attempt servicing until IRD power
and vessel input power are
disconnected.
TracVision 4 Field
Replaceable Units
4-2
Check all connectors on the Antenna Baseplate
and IRD. Remove connectors and examine for
signs of corrosion; clean as needed.
Semi-Annually
Remove the radome and examine the interior of
the Antenna Unit for signs of corrosion, loose
connections, or frayed or broken wires.
4.3
The TracVision 4 has been designed with durability and low
maintenance in mind. If you experience an operating problem or
otherwise require technical assistance, contact your local
authorized TracVision 4 dealer/installer or distributor first. If an
authorized dealer/installer or distributor is not located nearby,
contact KVH or KVH Europe directly at the telephone, facsimile,
or e-mail listings inside the front cover.
Replacement part numbers for field replaceable units (FRUs) that
can be serviced in the field are listed in Table 4-1. These parts
may be obtained from any KVH authorized dealer/installer or
may be ordered directly from KVH.
FRU
Table 4-1
Radome
CPU
RF Detector PCB
Antenna Gyro Sensor
Antenna Gyro Gasket
Elevation Drive Belt
LNB Assembly
Data Cable
PC Cable
Power Cable
RF Cable
IRD Ground Wire
CPU Fuse
TracVision 4 Field
Replaceable Units
Part Number
02-0925-04
02-0992
02-1017-02
02-1035
24-0139
24-0105-83
02-0932
32-0619-50
32-0628-06
32-0510-50
32-0417-50
32-0583-50
16-0017-4000