Electrostatic discharge (ESD) grounding strap
Four mounting screws (8-32 x 1.25 in. or M4 x 30 mm)
Phillips (+) screwdriver, number 2
Management host, such as a PC or laptop, with a serial port
Two wall-mount brackets
Eight wall-mount bracket screws
Hollow wall anchors capable of supporting the weight of a fully loaded NFX150 device, up to 20 lb (9 kg)—if you are mounting
the device in sheetrock (wall board with a gypsum plaster core) or in wall board not backed by wall studs
Grounding cable (minimum 14 AWG (2 mm²), minimum 90°C wire), grounding lug (Panduit LCC10-14BWL or equivalent), a
pair of 10-32x.25-in. screws, and a pair of flat washers
For information about installing the grounding cable, see the NFX150 Hardware Guide available at:
https://www.juniper.net/documentation/en_US/release-independent/junos/information-products/pathway-pages/nfx-series/product/
To mount the device on a wall:
Attach the wall-mount brackets to the sides of the chassis using the four wall-mount bracket screws on each side.
1.
Figure 3: Mounting the NFX150-C-S1 Device on a Wall
Install four mounting screws on the wall.
2.
Drill a hole A and install a mounting screw.
a.
Drill a hole B at a distance of 5.98 in. (15.19 cm.) on a level line to the right from hole A and install a mounting screw.
b.
Copyright © 2018, Juniper Networks, Inc.
NFX150-C-S1 Network Services Platform Quick Start
3