Configuration Via Serial Interface - Belkin OmniView User Manual

Remote ip manager
Hide thumbs Also See for OmniView:
Table of Contents

Advertisement

2-4 Configuration via Serial Interface

To configure the RIPM via serial interface, a null modem cable is required
(provided). Connect the null modem cable to the "Serial 01" port on the RIPM
and the other end to the serial port on the computer. The serial interface needs
to be adjusted with the parameters as shown below:
Use a terminal software program (e.g., HyperTerminal) to connect to the RIPM.
Reset the RIPM and immediately press the "ESC" key. You will see a "=>"
prompt. Enter the command "config" and press the "ENTER" key. You will be
asked to adjust the IP auto configuration, the IP address, the net mask, and the
default gateway. Pressing the "ENTER" key without entering values does not
change settings. The gateway value has to be set to "0.0.0.0" (for no gateway)
or any other value for the IP address of the gateway. After the confirmation, the
RIPM performs a reset using the new values as set before.
Parameter
Bits/second
Data bits
Parity
Stop bits
Flow control
Value
115200
8
no
1
none
Installation
1
2
3
4
5
6
14