Removal Of Pcbs / Electrical Components - Daikin RMKS112EV1A Service Manual

Removal procedure
Hide thumbs Also See for RMKS112EV1A:
Table of Contents

Advertisement

Si181180
1.2

Removal of PCBs / Electrical Components

Procedure
Step
1
Remove the 2 screws
of the terminal
mounting plate.
2
Remove the screw
above the electrical
component assembly.
3
Unfasten the clamp
from the terminal
mounting plate.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal mounting plate
Points
Preparation
Remove the outer panels
according to the "Removal of
Outer Panels".
M5(3) × 12
(R12966)
M5(3) × 12
(R9220)
(R9221)
Outdoor Unit
5

Hide quick links: