Download Print this page

Removal Of Electrical Components Assy - Daikin RN50HV1A Service Manual Removal Procedure

5.0 kw class outdoor unit

Advertisement

Si011084

4. Removal of Electrical Components ASSY

Procedure
Step
1
Remove the nut and
remove the terminal
cover.
2
Disconnect the
compressor lead wires.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Washer-fitted
nut
Rubber washer
Terminal cover
Red(R)
Blue(C)
Removal of Electrical Components ASSY
Terminal cover
(R5414)
(R5415)
Yellow(S)
(R5416)
Points
C
R
S
(R13618)
S : yellow
C : blue
R : red
9