Setting the SQL TAIL LENGTH
Enables setting the time duration of the downlink transmit after the uplink signal ceases.
1 Touch [ SETUP ] , then touch [ F ] , and then touch [ TIMER ] .
2 Touch [ SQL TAIL LENGTH ] .
The set value will change in the following sequence each time [ SQL
TAIL LENGTH ] , [ ▲ ], or [ ▼ ] is touched.
à "0ms" à "50ms" à "100ms" à ..................... à "2500ms" à
3 Touch [ BACK ] 3 times.
The setting is determined and the display will return to the operation
mode screen.
Factory default: 0ms
Set the ID announcement for analog FM mode
Set the announcement mode
1 Touch [ SETUP ] , then touch [ F ] , and then touch [ ID ANNOUNCE ] .
2 Touch [ ANNOUNCE ], then touch [ ANNOUNCE MODE ] .
The set value will change in the following sequence each time
[ ANNOUNCE MODE ] , [ ▲ ], or [ ▼ ] is touched.
à "CW" à "CW wo TONE" à "VOICE" ø à
ø: Requires optional Voice Guide Unit FVS-2.
3 Touch [ ANNOUNCE LEVEL ] .
The set value will change in the following sequence each time [ ANNOUNCE LEVEL ] , [ ▲ ], or [ ▼ ] is touched.
"HIGH"
"MID"
à
à
4 Touch [ CW ID SPEED ] .
The set value will change in the following sequence each time [ CW ID SPEED ] , [ ▲ ], or [ ▼ ] is touched.
à "16wd/min" à "20wd/min" à "24wd/min" à "32wd/min" à
5 Touch [ BACK ] 4 times.
The setting is determined and the display will return to the operation mode screen.
z Factory default:
ANNOUNCE MODE: CW
ANNOUNCE LEVEL: MID
CW ID SPEED: 20wd/min
z When operating in the USA the CW ID SPEED setting time must not exceed 20 words per minute when keyed by an
automatic device, to comply with the FCC rule Part 97: Sec. 97.119 (b)(1) Station identification.
Set announcement time interval
1 Touch [ SETUP ] , then touch [ F ], and then touch [ ID ANNOUNCE ] .
2 Touch [ INTERVAL ] .
The set value will change in the following sequence each time
[ INTERVAL ], [ ▲ ], or [ ▼ ] is touched.
à "OFF" à "3min" à "5min" à "10min" à
3 Touch [ BACK ] 3 times .
The setting is determined and the display will return to the operation mode screen.
z Factory default: 10min
z When "CW wo TONE" or "VC wo TONE" on "ANNOUNCE MODE" is set, the time interval is fixed at 10 minutes.
z When operating in the USA, the ID setting time should be ten minutes or less to comply with the FCC rule Part 97:
Sec. 97.119 (a) Station identification.
26
à "VC wo TONE" ø (VOICE wo TONE) à
"LOW"
à
à
à "15min" à "20min" à "30min" à "TOT" à
S E T U P
U P
L
I
N K
8
7
ID MODE
D O W N
L
I
N K
���������
TIMER ID ANNOUNCE
D G - I D
SQL
DEVIATION
MODE/REMOTE
ID SET
R - O F F
WIDE
T - O F F
Tx PW R
V
/
M
S Q L
BACK
BACK
H I
S E T U P
U P
L
I
N K
8
7
ID MODE
D O W N
L
I
N K
���������
TIMER ID ANNOUNCE
D G - I D
SQL
DEVIATION
ID SET
MODE/REMOTE
R - O F F
WIDE
T - O F F
Tx PW R
V
/
M
S Q L
BACK
BACK
H I
S E T U P
U P
L
I
N K
8
7
ID MODE
D O W N
L
I
N K
���������
TIMER ID ANNOUNCE
D G - I D
SQL
DEVIATION
ID SET
MODE/REMOTE
R - O F F
WIDE
T - O F F
Tx PW R
V
/
M
S Q L
BACK
BACK
H I
F
F
F