Selecting the Best Location for Proper Installation

2.3.1
Selecting the KSU Installation Site
When a site is selected for the installation of the KSU the
following conditions should be considered to ensure proper
installation.
KSUs are normally wall mounted to protect against
accident or flooding.
The KSU should not be located directly beneath
pipes. Should leaks or condensation occur, damage
could be caused to the Xen system equipment.
The area where the KSU is located must be free of
corrosive and inflammable gases, excessive chemical
or industrial dusts, and other materials that could
cause a hazard to personnel or to the proper
functioning of the equipment.
The operating ambient temperature and humidity
must
be
within
the
Environmental Conditions in Chapter 2 System
Specifications.
The operation of the system is virtually noiseless and
allows wide selection of installation sites. Care should
be taken to ensure the KSUs do not present a hazard
to office traffic. To minimize cabling costs, a
centralized location should be chosen.
The KSU must be located at a site where it can easily
be connected to a dedicated AC power source.
Connect the KSU only to a dedicated AC receptacle
that is not being used for any other devices such as
computers, copiers, or facsimile machines. Ensure
that the AC outlet is properly grounded.
Avoid installing the KSU in the vicinity of a radio
receiver.