4.12.2
Installation
A maximum of 23 OPX(2)-U13 ETUs can be installed in
the Xen Master system (maximum of 46 ports) in slots
S1~S8 in the first, second or third KSU.
A maximum of 5 OPX(2)-U13 ETUs can be installed in the
Xen Axis system (maximum of 10 ports) in slots S3~S7.
The analogue extension can be located up to 6 kms away
using 24AWG single-pair wiring (maximum 1800
resistance, including the internal resistance of the
analogue device).
4.12.3
LED Indications
Live LED indications are listed below.
Blinking Red
Steady Red
Off
LED1 indications are listed below.
Steady Red
Off
4.12.4
Connectors
The OPX(2)-U13 ETU has one connector.
CN1
Normal Operation
Operation Stopped (power still on)
No Power
Some port(s) busy
All ports idle
Connects to the backboard