Henny Penny 500 Operator's Manual page 68

Pressure fryers with computron controls
Hide thumbs Also See for 500:
Table of Contents

Advertisement

• Inputs Status (High Limit, Drain Switch, Fan Switch, Module)
• Outputs Status (Fan, Module, Heat, Pressure)
NOTE: To exit from the Special Program Mode at any time, press and hold the
program button for 2 seconds.
Press and hold the program button while turning on the cook/pump switch.
1 1 ) )
"SPEC PROG" show in the displays, followed by
"DEG °F or °C". Press the timer button to change between °F or °C.
2 2 ) )
Press the program button to proceed to the next step.
3 3 ) )
"INIT—>" shows in the display, Press and hold the timer button to reset the
4 4 ) )
controls to factory settings. Display shows "In-3", "In-2", "In-1", followed by "INIT
SYS" and then "DONE".
Press the program button to proceed to the next step.
5 5 ) )
"PROG UNLK" or "PROG LOCK" show in the displays. Press the timer button to
6 6 ) )
change between "UNLK" and "LOCK". In the lock mode, the time and
temperature cannot be changed until the controls are unlocked.
Press the program button to proceed to the next step.
7 7 ) )
"FRYR" shows in the left display and the type of fryer shows in the right display.
8 8 ) )
press the up or down button to change the type.
• "ELEC" = Electric Model
• "GAS" = Gas Model
• "GAS SSI" = Gas Model With Solid State Ignition
Press the program button to proceed to the next step.
9 9 ) )
"INPUTS" shows in the display. Press the 1 button to display the status of the
1 1 0 0 ) )
inputs.
• "H" = High Limit
• "D" = Drain Switch
• "F" = Fan Switch
• "M" = MV Signal From Ignition Module On SSI Gas Fryers
A display showing "_" means an open condition; "*" means a closed condition.
Press the program button to proceed to the next step.
1 1 1 1 ) )
"OUTPUTS" shows in the display. Press 1 button to display the status of the
1 1 2 2 ) )
outputs.
• "P" = Pressure
• "I" = Ignition Module On SSI Gas Fryers
• "H" = Heat
• "F" = Fan (24V Gas Systems Only)
• "MV NO" = No 24V Gas System
56