Tec-Eye Menu Structure; Tec-Eye Acronyms; Main Status Screen; Figure 3 Quick Menu Icons - Bard MEGA-TEC W120AP Service Instructions Manual

Wall-mount air conditioner
Table of Contents

Advertisement

TEC-EYE Menu Structure

Quick Menu
Setpoints
Information
Alarm Log
Main Menu
System Configuration
Advanced System Configuration
I/O Configuration
Digital Inputs
Digital Outputs
Analog Inputs
Analog Outputs
Fans/Blowers
Manual EEV
On/Off
Alarm Logs
Settings
Date/Time
Language
Initialization
Serial Ports
Change Password
Logout
In addition to the menu structure above, there are also
Status and Alarm screens.

TEC-EYE Acronyms

MAT – Mixed air temperature
RAT – Return air temperature
SAT – Supply air temperature
OAT – Outdoor air temperature
OAH – Outdoor air humidity
Blower – Indoor blower speed
Fan – Outdoor fan speed
Econ – Free cooling
NOTE: Digital refers to On/Off whereas analog is a
variable input.

Main Status Screen

The main Status screen is the default start-up screen
and also the return screen after 5 minutes of no
activity. The screen can be accessed at any time by
pressing the ESCAPE key repeatedly.
The wall-mount unit address is displayed in the upper
right corner on the main Status screen (see Figure
1). The main Status screen also shows the current
date, time, mixed air temperature (MAT), return air
temperature (RAT), supply air temperature (SAT),
outdoor air temperature (OAT) and outdoor air humidity
(OAH). Blower speed, condenser fan speed, damper
position and unit status are also displayed. See Table 1
for wall-mount unit status messages.
The Quick Menu is accessible from the main Status
screen. Setpoints, Information and Alarm Log are
available through the Quick Menu. Pressing the UP or
TABLE 1
Unit Status Messages
Message
PLC is on and has not started
Waiting...
running the application yet.
Unit is on and in orphan mode with
Orphan Mode
no calls for heating or cooling.
Unit is on and communicating with
LC Online
the LC6000 with no heating or
Unit is operating with continuous
Cont. Blower
blower when no heating or cooling
Freecooling
Unit is actively economizing.
Unit is mechanical cooling while
Optimized Cool
Cooling
Unit is actively mechanical cooling.
Heating
Unit is taking measures to decrease
Passive Dehum
humidity without using extra energy.
Self Test
Unit is performing a run test.
Unit has major fault preventing
Off by Alarm
Unit has been turned off by the
Off by LC
Unit has been turned off by the
Off by Keyboard
Unit is in Emergency Ventilation.
Emergency Vent
LC6000 has an active hydrogen
Unit is in Emergency Cooling.
Emergency Cool
Indoor temperatures have exceded
Unit is in Emergency Off. LC6000
Emergency Off
has an active smoke alarm.
DOWN keys while on the main Status screen will change
the Quick Menu icon displayed (see Figure 3). Press the
ENTER key when the desired icon is displayed.
FIGURE 3
Quick Menu Icons
Data Log
Information
Description
cooling calls.
calls are present.
actively economizing.
Unit is actively heating.
operation.
supervisory controller.
local user.
alarm.
high temp alarms.
Setpoints
Manual
2100-671
Page
7 of 44