Process Control Results

The table below lists the process control results shown in SP 3821.
Number
10
Success
21
ID sensor correction error
22
ID sensor: LED adjustment error
31
Charge bias correction error
51
High Vmin (Bk), High K2 (Color) error
52
Low K2 (Color) error
53
High K5 error
54
Low K5 error
55
High development gamma
56
Low development gamma
57
Development bias adjustment error
58
Development bias adjustment error
90
No process control
99
Not successful
This error code does not usually occur. If no problem is observed with image density
and/or development gamma, nothing needs to be done. If an image problem such as
low image density is observed, check the following points: Transfer belt/PCU/ID
sensor/Toner bottle
Result
15
23-Feb-06
Notes
No error
SC 400
SC 418
SC 300 to 307
SP 3145 (see the note below
the table)
SP 3146 (see the note below
the table)
SP 3147 (see the note below
the table)
SP 3147 (see the note below
the table)
Gamma > 5.0 (see the note
below the table)
Gamma < 0.5 (see the note
below the table)
Vk >150V (see the note
below the table)
Vk < -150V (see the note
below the table)
-
Interrupt during the process
control (e.g. Door open)