G160 Service Manual

Fusing

Make sure that the fusing unit is cool before you touch it. The fusing unit can
be very hot.
Make sure to restore the insulators, shields, etc after you service the fusing
unit.

Thermistor and Thermostat

1.
Front door
2.
Fusing unit (see the Service Manual for G-P1 (G105/G16): 'Fusing Unit')
3.
Fusing unit guide plate [A] (
4.
Release the connector [B] from the fusing lower cover [C] (hook x 1).
5.
Fusing lower cover [C] (
x 4)
x 2)
10