Installation Of The Kalfire W Front Models In Combination With Combustible Materials (E.g. A Wooden Wall); Installation Of The Kalfire W65/38C In Combination With Combustible Materials (E.g. A Wooden Wall); Installation Of The Kalfire W90/47C In Combination With Combustible Materials (E.g. A Wooden Wall) - Kalfire W Series Installation And User Manual

Closed wood fires
Table of Contents

Advertisement

2.4.1 Installation of the Kalfire W front models in
combination with combustible materials
(e.g. a wooden wall)
When installing the fireplace, make sure to respect the recommended
distance from any combustible building materials:
Image: Cross-section of a front model Kalfire W
Combustible building materials behind the fire must also be
shielded or insulated by insulation material. The minimum
thickness (A) of the insulation material depends on the model
and type of fireplace. Refer to Table 1 for the required minimum
insulation thickness.
The distance from the back of the fireplace (or the side if the fire is
built into an alcove) to the insulation material must be a minimum
of 10 cm.
Ensure that windows are at a minimum distance of 100 cm
from the appliance.
11
Ensure that curtains, furniture and/or other combustible
materials are at a minimum distance of 150 cm from the
appliance.
* The floor the fireplace is placed on must be made of non-
combustible materials. The (combustible) floor in front of
the door opening must be protected (30 cm on both sides
and 50 cm in front of the appliance).
2.4.2 Installation of the Kalfire W65/38C in
combination with combustible materials
(e.g. a wooden wall)
When installing the Kalfire W65/38C pay attention to the distance
to combustible building materials:
Image: Cross-section of a corner Kalfire W65/38C
Combustible materials must be shielded by insulation material
with a minimum thickness of 5 cm. The distance from the back of
the fireplace to the combustible material must be a minimum of
10 cm.
* The floor the Kalfire W65/38C is placed on must be made
of non-combustible materials. The (combustible) floor in
front of the door opening must be protected to a distance
of at least 50 cm in front of the appliance (side/sides with a
glass door).
2.4.3 Installation of the Kalfire W90/47C in
combination with combustible materials
(e.g. a wooden wall)
When installing the Kalfire W90/47C pay attention to the distance
to combustible building materials:
Image: Cross-section of a corner Kalfire W90/47C

Advertisement