Kalfire W90/47C Model In Combination With Flammable Materials (E.g. A Wooden Wall); Kalfire W66/48C And W90/47S Models In Combination With Flammable Materials (E.g. A Wooden Wall); Kalfire W80/52T And W105/47T Models In Combination With Flammable Materials (E.g. A Wooden Wall) - Kalfire W60/51Fl Installation And Instructions Manual

Closed wood-burning fireplaces
Table of Contents

Advertisement

flammable materials must be protected by insulation material
that is at least 5-cm thick (Kalfire w65/38C). The distance from
the back or the side of the fireplace to the insulation material
must be a minimum of 10 cm.
DANGER! The floor on which you place the Kalfire w65/38r
must consist of non-flammable materials. The floor in front
of the door opening must be protected to a distance of
at least 50 cm in front of the appliance (sides with a glass
door).
2.6. Kalfire W90/47C model in combination with
flammable materials (e.g. a wooden wall)
during installation, pay attention to the distance to the flammable
building materials:
100
figure 5: Cross-section of a Kalfire w90/47C model in combination with
flammable materials.
flammable materials must be protected by insulation material
that is at least 10-cm thick (Kalfire w90/47C.
DANGER! The floor on which you place the Kalfire w90/47r
must consist of non-flammable materials. The floor in front
of the door opening must be protected to a distance of
at least 50 cm in front of the appliance (sides with a glass
door).
2.7. Kalfire W66/48C and W90/47S models in
combination with flammable materials (e.g. a
wooden wall)
during installation, pay attention to the distance to the flammable
building materials:
figure 6: Cross-section of a Kalfire w 3-sided model in combination with
flammable materials
11
flammable materials must be protected by insulating material
that is at least 10 cm thick. The distance from the back or the side
of the fireplace to the insulation material must be a minimum of
10 cm.
DANGER! The floor on which you place the Kalfire w66/48s
or w90/47s must consist of non-flammable materials. The
floor in front of the door opening must be protected to a
distance of at least 50 cm in front of the appliance (sides
with a glass door).
2.8 Kalfire W80/52T and W105/47T models in
combination with flammable materials
(e.g. a wooden wall)
during installation, pay attention to the distance to the flammable
building materials:
figure 7: Cross-section of a Kalfire w tunnel model in combination with
flammable materials
flammable materials must be protected by insulation material
that is at least 10-cm thick. The distance from the rear and side of
the fireplace to the flammable material should measure at least
30 cm.
The floor on which you place the Kalfire w80/52t or w105/47t
must consist of non-flammable materials. The floor in front of the
door opening must be protected to a distance of at least 50 cm in
front of the appliance (sides with a glass door).