Safety; Ce-Marking; Safety Instructions Installer; Safety Instructions User - Kalfire W Series Installation And User Manual

Closed wood fires
Table of Contents

Advertisement

2 Safety

2.1 CE-marking

The appliance has been approved according to the CE standard
EN-13229-A2.
Every appliance that leaves the factory has been tested for
functionality according to the Kalfire quality standards.
National and local building and fire regulations apply to
the installation of the fireplace. Both local and national
requirements must be respected.
The relevant local authorities must be notified before
adding the external elements to the fireplace insert in
order to verify the quality of the installation.

2.2 Safety instructions installer

An authorised installer will connect the fireplace in
compliance with the national and/or local applicable
regulations.
Check if the fireplace functions correctly immediately
after the installation.
Take the necessary preventive measures, by using non-
combustible material, in order to prevent overheating of
floor, boards or walls close to the fireplace.

2.3 Safety instructions user

The Kalfire wood fire is only intended for use as an
additional heat source.
Careful! The exterior of the fireplace can become hot
during use.

2.3.1 Kalfire front models

Nr. 1: The distance between any built-in furniture and the
fireplace, should be at least 5 cm.
Nr. 2: The distance between any wall-, floor- and /or ceiling
material should be at least 1 cm.
Nr. 3+4: Make sure that curtains, furniture and/or other
combustible materials are at least 120 cm removed from the
fireplace. If a fireguard is used, this distance must be at least
40 cm.
9

2.3.2 Kalfire corner-, 3-sided and tunnel models

2
4
3
Nr. 1: The distance between any built-in furniture and the
fireplace, should be at least 5 cm.
Nr. 2: The distance between any wall-, floor- and /or ceiling
material should be at least 1 cm.
Nr. 3+4: Make sure that curtains, furniture and/or other
combustible materials are at least 100 cm removed from the
fireplace. If a fireguard is used, this distance must be at least
40 cm.