Reducer Ring; Mounting The Damper - Kalfire W Series Installation And User Manual

Closed wood fires
Table of Contents

Advertisement

3.6.2 Reducer ring

The Kalfire W is delivered as standard with a reducer ring
(except for Kalfire W66/48S). This ring can be used to
connect various flue systems to the Kalfire.
Table 4: Diameter chimney connection collar
Kalfire type
W45/48F
W60/51F, W70/33F
W85/40F
W71/62F, W100/61F,
W105/47F, W120/38F
W65/38C
W66/48S, W80/52T
W90/47C, W90/47S,
W105/47T
Kalfire W65/38C
Connection to a Ø200 flue duct is only possible with a chimney
duct of minimum 4.5 metres and maximum 6 metres long.
Kalfire W66/48S
Connection must remain Ø200 flue, reduction is not allowed.
Kalfire W90/47S
Connection to a Ø300 flue duct is only possible with a chimney
duct of minimum 4.5 metres and maximum 6 metres long.
22
Connection collar (mm)
Ø148 ±2
Ø178 ±2
Ø198 ±2
Ø248 ±2
Ø178 ±2
Ø198 ±2
Ø248 ±2
Figure 2 Reducer ring
A (mm)
B (mm)
Ø156 ±1
Ø136 ±1
Ø186 ±1
Ø166 ±1
Ø206 ±1
Ø186 ±1
Ø256 ±1
Ø236 ±1
Ø186 ±1
Ø166 ±1
Ø206 ±1
Ø186 ±1
Ø256 ±1
Ø236 ±1

3.7 Mounting the damper

The Kalfire W is delivered as standard without a damper. A damper
can be used to influence the degree of draught (suction) in the
flue. With the Kalfire W an external damper can be added. If there
is too much suction in the flue, we advise you to use a damper.
The amount of draught can be tested when you ignite the fire to
test the operation of the appliance. Pay extra attention to this
aspect, if the flue is longer than 7 metres. Normally the Kalfire W
can be controlled well using the air regulation (see section 5.3).
Attention
Make sure that the position of the damper is visible for the
end user. For this purpose, most of the operating knobs
have a position indication
(Open = Auf or +, Closed = Zu or -).
Check the functioning of the damper before completing the
installation of the fireplace.
Make sure that the end user is familiar with way the damper
functions.
C (mm)
Ø152 ±1
Ø182 ±1
Ø202 ±1
Ø248 ±1
Ø182 ±1
Ø202 ±1
Ø248 ±1