Menu - Wired Network Setup: Static Ip Address; Menu - Security; Staff Access Management; Reset Passwords - QSC MP-M80 User Manual

Music & paging zone mixer
Hide thumbs Also See for MP-M80:
Table of Contents

Advertisement

Menu – Wired Network Setup: Static IP Address
IMPORTANT!: Connect an Ethernet router
to the mixer's RJ45 jack.
Using a
ired Network Setup with a Static IP
Address provides wired communications between a
MP-M and a wireless Ethernet router. Make sure there is
no other equipment connected to the same network with
the same IP address.
1. Mixer Name!: – Enter a name for the network.
2. Network Type: – Set to
3. Select Static IP Address to use a static IP address
for the mixer.
4. Enter the Network Address for the mixer.
5. Enter the Network Mask
6. Enter the Nateway Address
7. Connection Status!:
a. Connected – Displays to confi rm successful
connection to the network. External devices may
now login to the mixer using the external network
Name and Password.
b. No Cable Detected – Mixer is not connected to a network.
8. Apply – Touch apply and the mixer will confi gure the network connections. .
Menu – Security
Security Setup is used to change the Admin
Passwords for the MP Install and MP Manage apps. The
default passwords are shown in the image below. These
should be changed to prevent unauthorized access.
Touch one of the Set Password fi elds to display a
keyboard and enter a new password.
1. MP Install – The MP Install password allows access
to and control of all MP-M functions.
2. MP Manage – The MP Manage password allows
access to the functions that let a manager grant
access to users of smartphones with the MP Manage
app installed. See the MP Manage and Smartphone
sections of this document for more detail.

Staff Access Management

The fi rst staff member to access the mixer with MP
Manage app must use the manager password that was
entered by the installer. If the password is forgotten, use
the reset procedure to return the passwords to the factory
defaults. From then on, the associated device is authorized
for all access.

Reset Passwords

If Installer and Manager passwords are lost, they may be reset to the factory programmed defaults by pushing and holding the "Reset" pin-hole
switch (located next to the MFC RJ-45 jacks) for 2 seconds.
TD-001578-01-A
ired.
1
3
4
5
6
7
8
1
2
51
Touch
Touch
Menu
Network
2
Touch
Touch
Menu
Security

Hide quick links: