Screen Descriptions - YASKAWA PVI 23 TL Installation And Operation Manual

Table of Contents

Advertisement

PVI 23TL, 28TL Installation and Operation Manual (Rev J)
9.2

Screen Descriptions

9.2.1 Main Screen (Default)
Press ESC to move from the Main (Default) screen into the Start Menu.
9.2.2 Start Menu
1. Operation Info
2. Alarm
3. History
4. Settings
5. Power Dispatch
9.2.3 Operation Info Menu
The Info Menu displays the data stored in the inverter memory. Use the
and DOWN through the list. Pressing
1 OP.Info
DOCR-070365-J
will take the screen back to the Start Menu.
AC Energy (EDay)
EDay
23.5kWh
Energy (kWh)
PDayPk 19kW
DayT
12 .1 h
AC Power Output (PDayPk)
(kW)
Run Time (DayT)
Uab
400.2V
Ubc
400.9V
Uca
399.7V
AC1 Voltage (Uab)
Freq
60.0Hz
AC2 Voltage (Ubc)
AC3 Voltage (Uca)
Ia
13.9A
AC Freq.
Ib
14.1A
Ic
13.1A
AC1 Current (Ia)
AC2 Current (Ib)
AC3 Current (Ic)
Tmod
78.2C
Tamb
50 C
Heatsink Temperature
Ambient Temperature
Upv 1
360.0V
Ipv1
14.7A
DC Voltage (Upv1)
Upv 2
360.4V
DC Current (Ipv1)
Ipv2
14.3A
DC Voltage (Upv2)
DC Current (Ipv2)
Sac
17KVA
Pac
16.7kW
Sac
Pac
Table 9.3 – Operation Information Submenu
buttons to scroll UP
Cumulative AC
AC Power Output
Hours
AC Voltage (V)
AC Voltage (V)
AC Voltage (V)
AC Frequency (Hz)
AC Current (A)
AC Current (A)
AC Current (A)
°C
°C
DC Voltage (V)
DC Current (A)
DC Voltage (V)
DC Current (A)
Apparent Power (kVA)
Real Power (kW)