Trouble-Shooting Symptoms - Quadra-Fire Classic Bay 1200 Service Manual

Insert pellet stove
Hide thumbs Also See for Classic Bay 1200:
Table of Contents

Advertisement

CB1200-I PELLET STOVE SERVICE MANUAL
A. PLUG IN STOVE -- NO RESPONSE
1) CHECK THE POWER SUPPLY FOR 115 VOLTS
2) CHECK THE FUSE IN THE JUNCTION BOX (7 AMP)
3) CHECK SNAP DISC #3 FOR POWER
4) CHECK CONTROL BOX
B. CALL LIGHT ON -- NO FIRE -- NO FUEL IN FIREPOT
1) CHECK HOPPER FOR BRIDGING OF PELLETS
2) PUSH RESET BUTTON & ADJUST FEED ADJUSTMENT PLATE
3) CHECK THERMOCOUPLE
4) CHECK VENTING SYSTEM FOR OBSTRUCTIONS
5) CHECK VACUUM SWITCH AND VACUUM HOSE
6) CHECK FEED MOTOR
7) CHECK EXHAUST BLOWER
C. CALL LIGHT ON -- NO FIRE -- PARTIALLY BURNED FUEL IN POT
1) CHECK FIREPOT AND CLEAN
2) CHECK THERMOCOUPLE
*GREEN LIGHT-----2.5 mV (+.5mV)
*RED LIGHT---------12.1 mV (+ 1mV)
3) CHECK INITIAL FEED TIME (1 MINUTE 35 SECONDS)
D. CALL LIGHT ON -- NO FIRE -- FUEL IN FIREPOT
1) CHECK FIREPOT FOR "CLINKER" MATERIAL
2) CLEAN FIREPOT
3) CHECK IGNITER
4) CHECK CONTROL BOX
7-31-2002
TROUBLE SHOOTING & REPAIR
PAGE 3
250-7700

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb1200Cb1200-i

Table of Contents