Quadra-Fire CB1200 Installation Manual

Quadra-Fire CB1200 Installation Manual

Pellet insert
Hide thumbs Also See for CB1200:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
CB1200 PELLET INSERT
APPLIANCE
MODEL:
CB1200I-C
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal injury,
or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
Alert children and adults to hazards of
high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
NOTE: To obtain a French translation of this
manual, please contact your dealer or visit
www.quadrafire.com
REMARQUE : Pour obtenir une traduction française de
ce manuel, s'il vous plaît contacter votre
revendeur ou visitez
7027-804G
WARNING
WARNING
CAUTION
www.quadrafire.com
05/21

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire CB1200

  • Page 1 INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instructions is CB1200 PELLET INSERT not followed exactly, a fire could result APPLIANCE causing property damage, personal injury, or death.
  • Page 2: Table Of Contents

    G. Pipe Selection Chart ......17 Quadra-Fire is a registered trademark of Hearth & Home Technologies.
  • Page 3: Important Safety Information

    CB1200 Pellet Insert Important Safety Information A. Appliance Certification B. BTU & Efficiency Specifications Emissions Report #: 0061PN013E Model CB1200 Pellet Insert EPA Certification #: 171-19 Laboratory OMNI Test Laboratories, Inc. EPA Certified Emissions: 0.8 grams per hour Safety 061-S-13-2 Report No.
  • Page 4: Glass Specifications

    CB1200 Pellet Insert I. California - Prop65 C. Glass Specifications This appliance is equipped with 5mm ceramic glass. WARNING Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. This product and the fuels used to operate this product (wood), and...
  • Page 5: Getting Started

    CB1200 Pellet Insert Install Guide Getting Started A. Design, Installation & Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: Considerations • Windows 1. Appliance Location • Air Intakes • Air Conditioner NOTICE: Check building codes prior to installation.
  • Page 6: Thermostat Wall Control Location

    CB1200 Pellet Insert C. Tools And Supplies Needed WARNING Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace: Risk of Fire! Reciprocating Saw • Damaged parts could impair safe Channel Locks operation. Hammer •...
  • Page 7: Install Checklist

    CB1200 Pellet Insert E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________...
  • Page 8: Dimensions And Clearances

    CB1200 Pellet Insert Dimensions and Clearances A. Appliance Dimensions 29-1/4 in [743mm] 22 in [559mm] 29-1/4 in [743mm] 8-3/4 in [223mm] 22 in [559mm] 8-3/4 in [223mm] 12-3/8 in 13 in [315mm] 10-7/8 in [330mm] 12-3/8 in [277mm] 13 in...
  • Page 9: Clearance To Combustibles, Ul And Ulc

    Figure 9.1 NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert appliance must be supplied in addition to this part.
  • Page 10: Masonry Chimney And Fireplace Clearances

    CB1200 Pellet Insert C. Masonry Chimney and Fireplace D. Minimum Opening for Masonry & Clearances ZC Fireplaces TOP TRIM 19-3/4 in 19-3/4 in (502mm) (502m) 28-1/2 in (724mm) Figure 10.3 18-1/4 in HEARTH Location Inches Millimeters (464mm) EXTENSION Height (Maximum Figure 10.1...
  • Page 11: Floor Protection

    *See Thermal Resistance: R value. NOTE: A Quadra-Fire floor protector (Part 811-0730) is available through your dealer to be used as a floor protector for the section under the insert body only. Floor protection to front and sides of insert appliance must be supplied in addition to this part.
  • Page 12: Installation Into A Factory-Built Fireplace

    CB1200 Pellet Insert G. Installation into a Factory-Built Fireplace The following is only one example as there are many different models of factory-built fireplaces. The following modifications are permissible: Removal of damper or locked in open position NOTE: This example is for reference only. Any...
  • Page 13: Installation Into A Masonry Fireplace

    CB1200 Pellet Insert H. Installation into a Masonry Fireplace • No dilution air is allowed to enter the chimney. a. Secure the fireplace damper in the open position. If All modifications that can be made to a Factory Built this cannot be accomplished, it will be necessary to Fireplace can be made to a Masonry Fireplace.
  • Page 14: Vent Information

    CB1200 Pellet Insert Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Restricted Area Air Supply Inlet Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.
  • Page 15: Avoiding Smoke And Odors

    CB1200 Pellet Insert B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical Power configuration the frequency of power outages should Failure be considered: • Power outages during operation will cause the...
  • Page 16: Negative Pressure

    • Imbalances of the HVAC air handling system 2. Mobile Home: Approved for all Listed pellet vent. • Upper level air leaks such as: A Quadra-Fire Outside Air Kit must be used with manufactured home installations. - Recessed lighting - Attic hatch 3.
  • Page 17: Equivalent Feet Of Pipe

    CB1200 Pellet Insert F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size (Figure 17.1). Vent surfaces get HOT, can cause burns if touched.
  • Page 18: Venting Systems

    CB1200 Pellet Insert Venting Systems A. Direct Connect with Outside Air B. Direct Connect without Outside Air NOTE: In Canada, only a full reline is allowed per ULC S628-93, ORD ULC C1482-M1990. NOTE: • Use non-combustible materials around exhaust vent pipe and...
  • Page 19: Full Reline With Outside Air - Horizontal

    CB1200 Pellet Insert C. Full Reline With Outside Air - Horizontal WARNING CAUTION Fire Risk. Never draw outside combustion air from: Inspection of Chimney: • Wall, floor or ceiling cavity • Masonry chimney must be in • Enclosed space such as an attic or garage good condition.
  • Page 20: Full Reline With Outside Air - Vertical

    CB1200 Pellet Insert D. Full Reline With Outside Air - Vertical NOTE: In Canada only a full reline is allowed per ULC NOTE: Check clearances carefully for this type of S628, ORD ULC C1482-M1990. installation to ensure adequate room for outside air venting.
  • Page 21: Appliance Set-Up

    CB1200 Pellet Insert Appliance Set-Up 2. Using a Phillips head screwdriver and two screws to A. Rear Shroud Installation attach Filler Bracket (Figure 21.3). Tools Required: Electric drill, #26 drill bit, Phillips screwdriver, 3/8 inch wrench, and 7/16 inch socket wrench.
  • Page 22 CB1200 Pellet Insert 4. Install the left shroud panel corner; 2 screws into 8. Assemble the right shroud panel corner and the right back of hopper and 1 screw down into the filler shroud panel using 3 screws (Figure 22.5).
  • Page 23: Outside Air Kit Instructions

    12. Using the electric drill with #26 drill bit; drill 2 holes into the left side of the hopper. Add two screws to secure NOTE: A Quadra-Fire outside air kit; 811-0872, is shroud assembly to the appliance (Figure 23.1). available through your Quadra-Fire Dealer to be used as a the outside air option, but is required for mobile home installations.
  • Page 24: Adjustable Hopper Options

    CB1200 Pellet Insert C. Adjustable Hopper Options Charred Areas in the Back Depending on your installation, the hopper can be adjusted down 2-1/2 inches (64mm) and will decrease in capacity from 75lbs to 60lbs. To adjust hopper: Top Log Top Log, Left 1.
  • Page 25: Panel And Trim Set

    CB1200 Pellet Insert E. Panel and Trim Set 6. Hold side curtains in open position and lower panel set over insert setting lower edge of top panel in slot Standard Size: 30 inches H x 40 inches W between hopper lid and panel support as shown in (762mm x 1016mm) Figure 25.5.
  • Page 26: Thermostat Installation And Operation

    CB1200 Pellet Insert F. Thermostat Installation and Operation The kit comes with a programmable wall thermostat and 25’ of thermostat wire. If you need to run more than 25’ make sure you use a continuous strand of 18 to 22 gauge thermostat wire.
  • Page 27: Mobile Home Installation

    CB1200 Pellet Insert Mobile Home Installation You must use a Quadra-Fire Outside Air Kit 811-0872 CAUTION for installation in a mobile home. 1. An outside air inlet must be provided for the THE STRUCTURAL INTEGRITY OF THE MOBILE combustion air and must remain clear of leaves, debris, ice and/or snow.
  • Page 28: Reference Materials

    CB1200 Pellet Insert Reference Materials A. Service & Maintenance List Date of Service Performed By Description of Service 7027-804G 05/21...
  • Page 29: Accessory List

    CB1200 Pellet Insert B. Accessory List CB1200I-C Service Parts Beginning Manufacturing Date: May 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 30 CB1200 Pellet Insert CB1200I-C Service Parts Beginning Manufacturing Date: May 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 31 CB1200 Pellet Insert 7027-804G 05/21...
  • Page 32 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL •...

This manual is also suitable for:

Cb1200i-c

Table of Contents