Fluid Control Module Repair; Cover Reattachment - Graco 26A010 Instructions Manual

Aintegrated air control
Table of Contents

Advertisement

Repair
Fluid Control
Control Module
Module Repair
Fluid
Fluid
Control
Module
1. Disconnect all of the cables leading to and from
the Fluid Control Module cube.
2. Remove the Fluid Control Module cube top (6) by
using a 5/16" Allen wrench loosen two screws.
Removing the top exposes the Fluid Control
Module base (7), the grounding screw (33), and
the four mounting screws (32).
3. Remove the grounding screw (33).
4. Remove the four mounting screws (32).
5. Remove the Fluid Control Module base (7).
6. Separate the Fluid Control Module top (6) and
base (7) of the new FCM, as described in Step 2.
7. Orient the Fluid Control Module base (7) so that
the two ports are facing right, and secure the
base to the enclosure with the four mounting
screws (32).
20
Repair
Repair
8. Reconnect the grounding screw (33).
9. Orient the Fluid Control Module top (6) so that
ports 5–7 are facing to the left, and secure the
top to the base using a 5/16" Allen wrench to
tighten the two screws.
10. Reconnect the cables .

Cover Reattachment

Cover
Cover
Reattachment
Reattachment
1. Align the slotted holes on the cover (14) with the
two upper screws (31) on the enclosure panel
(15).
2. Secure the bottom of the cover (14) to the
enclosure panel (15) with the two bottom screws
(31), and tighten the two upper screws (31).