Viessmann VITODENS 242-F Technical Manual page 57

Gas condensing storage combi boiler 1.9 to 35.0 kw for natural gas and lpg gas condensing storage combi boiler 1.9 to 26.0 kw for natural gas and lpg gas/solar condensing storage combi boiler with solar dhw heating 1.9 to 26.0 kw for natural gas and lpg
Table of Contents

Advertisement

Design information
Connection sets for installation on finished walls, for connection to the left or right
Connection set without pre-mounting bracket, part no. 7347985
410
410
50
398
361
K
H
A
G
B
F
C
E
D
D
E
C
F
B
G
A
H
A Solar return R ¾/Ø 22 mm
B Heating flow R ¾
C DHW R ½
D Gas connection R ½
E DHW circulation R ½ (separate accessory)
Type
Vitodens 242-F, B2UB
Note
The adjustable feet give the height measurements of the connec-
tions a tolerance of + 7 mm.
For connecting on-site lines on the gas, heating water and DHW
sides from the left or right.
VITODENS
(cont.)
a
b
c
mm
mm
mm
1367
1422
1477
F Cold water R ½
G Heating return R ¾
H Solar flow R ¾/Ø 22 mm
K Balanced flue connection towards the back
d
e
f
mm
mm
mm
1532
1587
1592
Connection set comprising:
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain
& fill valve
■ 2 connectors for DHW
■ 2 connectors each for solar flow and return (R ¾/Ø 22 mm)
■ Gas shut-off valve with thermally activated safety shut-off valve
g
h
k
mm
mm
mm
1696
1752
1807
VIESMANN
5
l
mm
2021
57