Viessmann VITODENS 242-F Technical Manual page 24

Gas condensing storage combi boiler 1.9 to 35.0 kw for natural gas and lpg gas condensing storage combi boiler 1.9 to 26.0 kw for natural gas and lpg gas/solar condensing storage combi boiler with solar dhw heating 1.9 to 26.0 kw for natural gas and lpg
Table of Contents

Advertisement

Vitodens 242-F, type B2UB
Residual head of the integral circulation pump
650 65
G
600 60
550 55
F
500 50
450 45
E
400
40
350 35
D
300
30
3
C
250 25
B
200
20
A
150 15
100
10
50
5
0
0
0
100
Flow rate in l/h
H Upper operational limit
Curve
Pump rate, circulation
pump
A
B
C
D
E
F
G
Variable speed solar circuit pump in the Vitodens 242-F
The integral solar circuit pump is a highly efficient circulation pump
with substantially lower power consumption than conventional
pumps.
The min. and max. speed and thus the pump rate are set via codes
on the control unit. The control unit transmits the current default set-
tings to the circulation pump via an internal data bus.
In the delivered condition, the minimum pump rate (coding address
"05" in the solar group) is set to 30 %. The maximum pump rate
(coding address "06" in the solar group) is set to 100 %.
VIESMANN
24
(cont.)
200
300
400
500
600
Coding address setting "E6"
40 %
50 %
60 %
70 %
80 %
90 %
100 %
H
700
800
900
1000
1100
E6:040
E6:050
E6:060
E6:070
E6:080
E6:090
E6:100
Type
Rated voltage
Power consumption
Energy efficiency class
1200
1300
V~
max.
W
min.
W
VI Solar PM2
15-85
230
55
3
A
VITODENS

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2ubB2sbB2tb

Table of Contents