Viessmann VITODENS 242-F Technical Manual page 51

Gas condensing storage combi boiler 1.9 to 35.0 kw for natural gas and lpg gas condensing storage combi boiler 1.9 to 26.0 kw for natural gas and lpg gas/solar condensing storage combi boiler with solar dhw heating 1.9 to 26.0 kw for natural gas and lpg
Table of Contents

Advertisement

Design information
A wall clearance of 70 mm is required behind the Vitodens.
Note
The adjustable feet give the height measurements of the connec-
tions a tolerance of + 7 mm.
For connecting the on-site gas, heating water and DHW lines from
below.
Connection set for flush mounting with mounting plate, for pre-installation in unfinished buildings, part no. 7351625
330
220
55
50
G
AB CD
EF
AB CD EF
A Heating flow R ¾
B DHW R ½
C DHW circulation R ½ (separate accessory)
D Gas connection R ½
E Cold water R ½
F Heating return R ¾
G Balanced flue connection towards the back
VITODENS
(cont.)
Connection set comprising:
■ Fitting assembly
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain
& fill valve and air vent valve
■ 2 connectors for DHW
■ Angle gas valve with thermally activated safety shut-off valve
Type
Vitodens 222-F, B2TB
- 13 to 26 kW
- 35 kW
Vitodens 222-F, B2SB
Vitodens 333-F, B3TB
5
a
b
c
mm
mm
mm
1475
1496
1571
1675
1696
1771
1675
1696
1771
1475
1496
1571
VIESMANN
51