Viessmann VITODENS 242-F Technical Manual page 21

Gas condensing storage combi boiler 1.9 to 35.0 kw for natural gas and lpg gas condensing storage combi boiler 1.9 to 26.0 kw for natural gas and lpg gas/solar condensing storage combi boiler with solar dhw heating 1.9 to 26.0 kw for natural gas and lpg
Table of Contents

Advertisement

Vitodens 242-F, type B2UB
Gas boiler, type B and C, category II
Rated heating output range (to EN 15502-1)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
DHW cylinder
Capacity
Permiss. operating pressure (DHW side)
Continuous DHW output
For DHW heating from 10 to 40 °C
Performance factor N
*6
L
Initial DHW output
For DHW heating from 10 to 40 °C
Connection values
relative to max. load
With gas
Natural gas E
Natural gas LL
LPG P
*2
Flue gas parameters
Flue gas category to G 635/G 636
Temperature (at a return temperature of 30 °C)
– At rated heating output
– At partial load
Temperature (at a return temperature of 60 °C)
Mass flow rate
– For natural gas
– At rated heating output
– At partial load
– For LPG
– At rated heating output
– At partial load
Available draught
Max. amount of condensate
To DWA-A 251
Condensate connection (hose nozzle)
Flue outlet
Ventilation air connection
Standard seasonal efficiency [to DIN] at
T
/T
= 40/30 °C
F
R
Energy efficiency class
– Heating
– DHW heating, draw-off profile XL
*6
At 70 ºC average boiler water temperature and cylinder storage temperature Tcyl = 60 ºC.
DHW performance factor NL depends on cylinder storage temperature Tcyl.
Standard values: Tcyl = 60 ºC → 1.0 × NL Tcyl = 55 ºC → 0.75 × NL Tcyl = 50 ºC → 0.55 × NL Tcyl = 45 ºC → 0.3 × NL.
*2
Calculation values for sizing the flue system to EN 13384.
Flue gas temperatures as actual gross values at 20 °C combustion air temperature.
The flue gas temperature at a return temperature of 30 °C is significant for the sizing of the flue system.
The flue gas temperature at a return temperature of 60 °C is used to determine the application range of flue pipes with maximum permissi-
ble operating temperatures.
VITODENS
(cont.)
2N3P
kW
kW
Litre
bar
MPa
kW
l/h
l/10 min
m
3
/h
m
3
/h
kg/h
°C
°C
°C
kg/h
kg/h
kg/h
kg/h
Pa
mbar
l/h
Ø mm
Ø mm
Ø mm
%
1.9 - 13.0
1.9 - 19.0
1.7 - 12.1
1.7 - 17.6
170
170
10
10
1
1
17.2
17.2
493
493
1.4
1.4
164
164
1.89
1.89
2.20
2.20
1.40
1.40
G
/G
G
/G
52
51
52
51
45
45
35
35
68
68
31.8
31.8
5.5
5.5
30.2
30.2
7.6
7.6
250
250
2.5
2.5
2.3
2.5
20-24
20-24
60
60
100
100
up to 98 (H
) [gross cv]
s
A
A
A
A
2.6 - 26.0
2.4 - 24.1
170
10
1
29.3
840
2.0
190
3.23
3.75
2.39
3
G
/G
52
51
45
35
70
43.9
8.7
41.7
14.0
250
2.5
4.3
20-24
60
100
A
A
VIESMANN
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2ubB2sbB2tb

Table of Contents