Note
Height dimensions in combination with a balanced flue bend
Ø 60/100 mm. In combination with a balanced flue bend
Ø 60/100 mm, the total height is reduced by 10 mm.
Variable speed heating circuit pump in the Vitodens 222-F
The integral circulation pump is a highly efficient pump with substan-
tially lower power consumption than conventional pumps.
The pump speed and consequently the pump rate are regulated sub-
ject to the outside temperature and the switching times for heating or
reduced mode. The control unit transmits the current default settings
to the circulation pump via an internal data bus.
2
The min. and max. speed and the speed in reduced mode can be
adjusted using codes at the control unit of the existing heating sys-
tem.
In the delivered condition, the minimum pump rate (coding address
"E7") and the maximum pump rate (coding address "E6") are set to
the following values:
Rated heating output in kW
13
19
26
Residual head of the integral circulation pump
650 65
G
600 60
550 55
F
500 50
450 45
E
400
40
350 35
D
300
30
C
250 25
B
200
20
A
150 15
100
10
50
5
0
0
0
100
Flow rate in l/h
H Upper operational limit
VIESMANN
16
(cont.)
Speed settings in the delivered
condition in %
Min. pump rate
Max. pump
rate
45
45
45
200
300
400
500
600
Note
In conjunction with a low loss header, heating water buffer cylinder
and heating circuits with mixer, the internal circulation pump runs at
a constant speed. The speed can be adjusted subject to demand by
changing the code at the control unit.
Specification circulation pump
Rated heating output
Circulation pump
Rated voltage
Power consumption
– max.
– min.
– Delivered condition
Energy efficiency class
Energy efficiency index (EEI)
60
65
80
H
700
800
900
1000
1100
kW
13
Type
UPM3
UPM3
15-75
15-75
V~
230
W
60
W
2
W
12
A
≤ 0.20
≤ 0.20
1200
1300
19
26
UPM3
15-75
230
230
60
60
2
2
20
38
A
A
≤ 0.20
VITODENS