IMPORTANT!
The power supply cable must be connected by an authorised service person
Feeder cable section
Use a type of cable according to the applicable local regulations.
220-240 Vac 3 x 10 mm2*
*Connection with wall box connection.
1 Remove the screws that hold the cover in place at the
back of the cooker
!5
ELECTRICAL FEEDER CABLE CONNECTION
IMPORTANT!
Do not to unscrew the
strain relief from the
cooker
2 Unscrew the bottom terminal end of the strain relief
by using two spanners. Insert terminal into the power
suply cable, then insert the feeder cable into the strain
relief (ensure sealing ring stays secured inside the
strain relief).
IMPORTANT!
The earth conductor should remain around 30mm
longer than the others
220-240 V AC
L
N
PE
3 Connect the live, neutral and earth cables to the
terminal as shown above. Lock the power supply cable
in place by screwing the terminal end back to the
strain relief. Re-mount the screw cover back onto to
the cooker.