Indicators and Projector Condition

Check the indicators for projector condition. For Alarm indicator, see pages 53-54.
Indicators
POWER
WARNING
red/green
red
• • • green.
• • • blinks green.
When the projection lamp reaches the end of its life, the LAMP REPLACE indicator lights yellow.
✽
When this indicator lights yellow, replace the projection lamp with a new one promptly. Reset the lamp
replacement counter after replacing the lamp. See pages 60-61.
LAMP
REPLACE
yellow
The projector is off. (The AC power cord is unplugged.)
The projector is preparing for stand-by or the projection lamp is
being cooled down. The projector cannot be turned on until cooling is
completed.
The projector is ready to be turned on with the ON/STAND-BY button.
The projector is operating normally.
The projector is in the Power management mode.
The temperature inside the projector is abnormally high. The projector
cannot be turned on. When the projector is cooled down enough and
the temperature returns to normal, the POWER indicator lights red
and the projector can be turned on. (The WARNING indicator keeps
blinking.) Check and clean the air filters.
The projector has been cooled down enough and the temperature
returns to normal. When turning on the projector, the WARNING
indicator stops blinking. Check and clean the air filters.
The projector detects an abnormal condition and cannot be turned on.
Unplug the AC power cord and plug it again to turn on the projector. If
the projector is turned off again, unplug the AC power cord and contact
the dealer or the service center for service and checkup. Do not leave
the projector on. It may cause an electric shock or a fire hazard.
• • • red
• • • blinks red.
Projector Condition
• • • off