Heater Contactors; Heating Elements - Vulcan-Hart VGCTS16 Service Manual

Round counter top tilting braising pans (16 gallon) gas and electric
Table of Contents

Advertisement

ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
4.
Remove the screws securing the high limit to
the underside of the pan.
5.
Reverse procedure to install a new hi limit and
check unit for proper operation.

HEATER CONTACTORS

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1.
Remove right console cover as outlined under
"RIGHT AND LEFT CONSOLE COVER".
2.
Remove component mounting plate to gain
access to contactors by removing nut from
threaded stud.
A.
Grasp plate and pull upwards while
rotating left to right to free it from bottom
fastener.
3.
Remove lead wires from contactor being
replaced.
4.
Remove contactor mounting screws.
5.
Reverse procedure to install a new contactor
and check for proper operation.

HEATING ELEMENTS

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1.
Remove bottom cover as outlined under
"BOTTOM COVER".
2.
Disconnect heater lead wires and mark
accordingly for proper replacement.
3.
Remove the two nuts from mounting stud that
secure the insulation pan to the bottom of the
braising pan.
4.
Push the heater lead wires back through the
opening in bearing to allow clearance for the
insulation pan to be lifted out.
5.
Remove the nuts securing the element clamp
to the braising pan bottom for the element
being replaced.
6.
Replace with a new element and reverse
procedure to install.
Page 9 of 24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml-114827Vects16Ml-114825