OUTPUT
Key 2: towards or away mode detection
REDIRECTION
Motion towards the detector triggers relay 1.
Motion away from the detector triggers relay 2.
OUTPUT
Press the OUTPUT CONFIGURATION key (17).
CONFIGURA-
Use the NUMBER keys 1-4 (1) to select the required output configuration :
TION
Detection
No Detection
During an adjustment session all parameters may be reset to their factory values in the following way :
PARAMETERS
ACTIONS
FACTORY
Press the SETUP key (19), then press the NUMBER key 9.
VALUES
All the parameters (except the access code) are reset to the factory values.
FACTORY VALUES :
Without remote control all of the parameters can be set using the 2 push buttons.
CONFIGURATION
Note: These two buttons are accessible from the sensor front cover with a small point.
WITH PUSH
• To adjust the sensor using the buttons :
BUTTONS
Press and hold either push button for 2 seconds (until the LEDs flash) and then
release the button ;
• To end adjusting the sensor using the buttons :
Press and hold either push button for 2 seconds (until the LEDs stop flashing) and
then release the button;
Note : if no button is pressed within 20 seconds the adjustment session is
automatically ended.
• To reset all the parameters to the factory values :
Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second (after 2 seconds).
During the manual adjustment session the red and green LEDs flash successively and continuously.
• The flashing number of the red LED provides the number of the displayed parameter (see next table);
• The flashing number of the green LED provides the value of the displayed parameter ;
Note: no green flashing indicates the zero value.
During the manual adjustment session :
• Each press on the right button increases the number of the displayed parameter by one unit ;
• Each press on the left button increases the value of the displayed parameter by one unit.
Note: When the maximum value or the highest number of the parameter is reached, it will return to its minimum values.
For example, to change the sensitivity from 7 to 9 and the rejection mode from "detection of all kind of targets in motion" to High
"Pedestrian/parallel traffic" rejection.
75.5268.01 20070111
Active
Passive
Parameter
Sensitivity
Hold time
Detection mode
Rejection mode
Output redirection
Output configuration
Press any button for 2 seconds to enter the adjustment session and then release it.
The red LED flashes once (1 = sensitivity) and the green LED flashes 7 times (sensitivity=7).
Press the left button twice to increase the sensitivity from 7 to 9.
The red LED still flashes once (1 = sensitivity) but the green LED flashes 9 times now (sensitivity=9).
Now press the right button 4 times to move to function 5 (rejection mode).
The red LED flashes 5 times (5 = rejection mode) and the green LED flashes once (detection of all kind of targets in motion)
Press the left button 4 times to set the parameter to High "Pedestrian/parallel traffic" rejection.
The red LED still flashes 5 times (5 = rejection mode) but the green LED flashes 5 times now (High "pedestrian/parallel traffic"
rejection).
Press any button during 2 seconds to end the adjustment session and then release it.
Towards or away mode detection only works if the detection
parameter is set to 1 (bi-directional). Otherwise the sensor
does not detect any motion anymore.
This works also if pedestrian rejection is enabled (immunity
parameter set to 3,4 or 5)
Factory Values Table
Values
0 - 9
0 - 9
1 - 3
1 - 5
0 - 2
1 - 4
Factory setting
7
0
2
1
0
1