BEA FALCON XL User Manual

BEA FALCON XL User Manual

Activation sensor for automatic industrial doors

Advertisement

Quick Links

DESCRIPTION
1
2
3
4

TECHNICAL SPECIFICATIONS

Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Detection zone (typical):
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
LED-signal:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Materials:
Weight:
Cable length:
Norm conformity:
Specifications are subject to change without prior notice.
* Other use of this device outside its permitted purpose cannot be guaranteed by the manufacturer.
** Measured in optimal conditions
1
INSTALLATION TIPS
Avoid vibrations.
75.5678.04 20111104
FALCON / FALCON XL
FALCON / FALCON XL
microwave doppler radar
24.125 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion/movement
*FALCON: 13ft (W) x 16ft (D) @ 16ft; FALCON XL: 13ft x 6.5ft @ 8ft 2in
** 2.2 in/s (measured in the sensor axis)
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
red: detection state, parameter indication; green: value indication
*FALCON: 11.5ft - 23ft; FALCON XL: 6.5ft - 11.5ft
IP65
from -22F to 140F (-30 °C to + 60 °C)
5 in (D) x 4 in (W) x 3 3/4 (H); (127 mm (L) x 102 mm (H) x 96 mm (W))
0° to 180° vertical
ABS and polycarbonate
.88lbs (400 g)
33 ft (10 m)
R&TTE 1999/5/EC; EMC 2004/108/EC
Do not cover the
sensor.
Activation sensor for automatic industrial doors*
FALCON: for normal to high mounting 11.5 ft - 23 ft (3.5 - 7 m)
FALCON XL: for low mounting 7 ft - 11.5 ft (2 - 3.5 m)
5
6
7
Avoid proximity to neon or
fluorescent lamps or moving
objects.
Users Guide
1.
push buttons
2.
LEDS
3.
front face
4.
radar antenna
5.
angle indication
6.
bracket
7.
cable
Only open the sensor
when the cable needs to
be replaced.
Page 1 of 5

Advertisement

loading

Summary of Contents for BEA FALCON XL

  • Page 1: Technical Specifications

    Transmitter power density: motion/movement Detection mode: Detection zone (typical): *FALCON: 13ft (W) x 16ft (D) @ 16ft; FALCON XL: 13ft x 6.5ft @ 8ft 2in Min. detection speed: ** 2.2 in/s (measured in the sensor axis) Supply voltage: 12V to 24V AC ±10%; 12V to 24V DC +30% / -10%...
  • Page 2: Dimensions (Inches)

    DIMENSIONS (INCHES) 1 1/2 1 9/16 1 1/4 1 1/16 1 1/16 1 1/16 4 1/8 6.25 6.25 Ceiling mounting Wall mounting Bracket dimensions POSSIBLE SETTINGS BY REMOTE CONTROL FIELD SIZE > > > > SENSITIVITY HOLD-OPEN TIME 0.5 s A = active output (relay active with detection) OUTPUT CONFIGURATION...
  • Page 3: Mounting And Wiring

    WALL Adjust the field size with the remote Adjust the angle of the sensor to position the detection field. control or the push buttons. FALCON FALCON XL FALCON Mounting height: 11.5 ft Mounting height: 16 ft Mounting height: 8 ft All detection field dimensions were measured in optimal conditions and with field size value 9.
  • Page 4: Troubleshooting

    TROUBLESHOOTING The door remains The sensor power is off. Check the wiring and the power supply. closed. The LED is OFF. Improper output The door does not react Check the output configuration setting on each configuration on the sensor. as expected. sensor connected to the door operator.
  • Page 5 Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.